2、GB/T129142."Paper and board -- Determination of tensile strength (Constant rate of elongation method)";
3、GB/T 24328.3"Tissue paper and tissue products -- Part 3: Determination of tensile strength, stretch at break and tensile energy absorption"
4、GB/T 24328.4"Tissue paper and tissue products -- Part 4: Determination of wet tensile strength";
5、GB/T20808-2022Tissue Paper standards.
" />【适用范围】
:适用于卫生纸、纸和纸板抗张强度、伸长率、裂断长和抗张能量吸收值的测定,也可用于其它低抗张强度、低伸长率片状材料的抗张性能试验。
【相关标准】
2、GB/T129142."Paper and board -- Determination of tensile strength (Constant rate of elongation method)";
3、GB/T 24328.3"Tissue paper and tissue products -- Part 3: Determination of tensile strength, stretch at break and tensile energy absorption"
4、GB/T 24328.4"Tissue paper and tissue products -- Part 4: Determination of wet tensile strength";
5、GB/T20808-2022Tissue Paper standards.
【适用范围】:适用于卫生纸、纸和纸板抗张强度、伸长率、裂断长和抗张能量吸收值的测定,也可用于其它低抗张强度、低伸长率片状材料的抗张性能试验。
【符合标准】:
ISO1924/2《纸和纸板—抗张强度的测定 第2部分:恒速拉伸法》;
GB/T12914《纸和纸板抗张强度的测定法(恒速拉伸法)》;
GB/T 24328.3《卫生纸及其制品 第3部分:抗张强度、断裂时伸长率和抗张能量吸收的测定》;
GB/T 24328.4《卫生纸及其制品 第4部分:湿抗张强度的测定》;
GB/T20808-2022纸巾等标准规定。
【技术参数】:
1、测量范围:1~100N;
2、分辨率:0.001N;
3、示值相对误差:示值误差≤1%,重复性误差≤1%;
4、零点、标定值相对漂移:≤0.2%;
5、长度测量范围:(46~200)mm;
6、伸长量测量准确度:±0.01mm;
7、试验速度调节范围:(2~200)mm/min(最佳);
8、试验速度误差:(2~10)mm/min:±1mm/min;(10~200)mm/min:±5%;
9、夹间距(试样长度/复位行程):可调(标准夹间距为100mm);
10、夹间距定位误差:±0.05mm;
11、动夹头复位误差:±0.05mm;
12、外形尺寸:700mm×400mm×300mm;
13、整机质量:约50kg。
【环境条件】:
1、室温:20℃±10℃。
2、电源:AC220V±22V,50Hz,最大电流5A,电源应可靠接地。
3、工作环境清洁,无强磁场和震动源,工作台平整稳固。